MAGNETOHYDRODYNAMICS / LIQUID-METAL FLOW

Magnetic control of
liquid-metal flow.

CFD simulation · 20-case study

Conceptual hardware illustration of a liquid-metal channel between magnet poles, with cyan flow arrows, a purple transverse field and a glowing heated wall
Conceptual hardware illustrationView original ↗

A flatter velocity profile.
A modest wall-temperature response.

Explore how magnetic-field strength redistributes lead–lithium flow across twenty numerical cases.

COMPARE THE NUMERICAL RESULTS

Change the field.
Explore the response.

Speed profile across the channel

Re 1,000 · Ha 10
Speed profile across the channelRe 1000, Ha 10. Solid line: selected case. Dashed line: Ha 0. Both use the same zero-field mean speed.00.250.50.75100.40.81.21.6V / Vrefy / H
Selected magnetic fieldZero-field reference

EXPLORE THE SAVED CASES

Reynolds number · Re
Sampled peak-speed decrease
23.5%
Axial-mean wall-line decrease
0.775 K

Compared with Ha = 0 at the same Re. Each curve uses all 100 exported samples.

Shared zero-field normalization preserves changes in peak speed. V is speed magnitude; the profile integral is not a mass-conservation check.

THE MAIN FINDING

Less peak speed.
A small thermal response.

At Ha = 10, sampled peak speed falls by 23.5–25.9% across Re = 250–1,000. The height-mean speed changes by less than 0.084%, showing how the profile redistributes.

The axial-mean wall-line temperature decreases by about 0.8 K. That is a different measure from the change in the maximum wall temperature, and it does not establish a system-level cooling or pumping benefit.

01 / THE MODEL & MY WORK

A heated channel.
A localized magnetic field.

The study connects a parametric Fluent model, CFD-Post line exports and reproducible numerical comparisons. The original simulation files provide the geometry, material properties, boundary conditions and case definitions.

Original conceptual schematic identifying the PbLi inlet, outlet, 10 mm channel height, flow direction, north and south magnet poles, applied magnetic field and heated wall
Conceptual view from the original study presentation. Hardware, heating layout and depth are illustrative; the verified numerical geometry and heating boundary are shown below.Full original schematic ↗
CHANNEL
300 × 10 mm
CASE MATRIX
4 Re × 5 Ha
LOWER-WALL HEAT FLUX
100 kW/m²
INLET TEMPERATURE
600 K
Verified channel domain and native mesh showing a 300 mm length, 10 mm height and magnetic field from 50 to 250 mm
Channel definition and actual mesh coordinates recovered from the native Fluent case. Vertical dimensions are enlarged for readability.Full size ↗

Physical definition

Fluid
Lead–lithium (PbLi) with constant properties
Heating
Lower wall: uniform 100 kW/m²
Upper wall: adiabatic
Field
Transverse, negative y direction
Applied over x = 50–250 mm
Outlet
0 Pa gauge pressure
Re
250, 500, 750 and 1,000
Based on Dh = 20 mm
Ha
0, 2.5, 5, 7.5 and 10
Based on half-height a = 5 mm

Numerical approach

  • 2D, steady, laminar, pressure-based, double-precision Fluent model.
  • Fluent MHD add-on momentum and energy source hooks.
  • Coupled pressure–velocity solution and second-order pressure, momentum and energy discretization.
  • 37,500 quadrilateral cells and 38,301 nodes in each of the 20 mapped cases.
  • 100 exported samples on each wall, centerline and cross-channel speed line.

The native state places the speed profile at x = 150 mm, the wall line at y = 0, and the centerline at y = 5 mm. The reported setup values and statistics were rechecked for this portfolio edition.

Material values and dimensionless definitions

Constant properties in the native setup: density 9,806 kg/m³, dynamic viscosity 0.00193 Pa·s, heat capacity 189.5 J/(kg·K), thermal conductivity 20.93 W/(m·K), and electrical conductivity 782,000 S/m.

Re = ρ Uin Dh / μ. Inlet speed ranges from approximately 2.460 to 9.841 mm/s. Ha = |B| a √(σ/μ) uses a = 5 mm; Ha = 10 corresponds to |B| ≈ 0.09936 T. The characteristic lengths for Re and Ha are different.

These values describe the saved numerical model. Temperature-dependent material behaviour and hardware operating limits have not been verified.

02 / RESULTS & INTERPRETATION

Keep the flow change
and thermal change in proportion.

Saved native cell fields show the speed redistribution at Re = 1,000. Each quantity uses a common colour scale for Ha = 0 and 10; the channel height is enlarged for readability.

Native Re 1000 speed and temperature contours for Ha 0 and Ha 10 on shared colour scales
37,500 cell values per case, drawn on the native mesh without smoothing or a new solve. Dotted lines mark the magnetic-field region. Temperature differences are small on the absolute scale.Full size ↗

All 20 cases, in detail

The same zero-field reference is used within each Reynolds-number group. Full-range profile figures use all 100 exported points per curve; detail views state their sampled range. Open the vector version to inspect fine detail.

Twenty normalized speed profiles across four Reynolds numbers and five Hartmann numbers
Original numerical profiles. Every curve at a given Re uses its zero-field height-mean speed as the reference.Open vector figure ↗
Ha = 10 compared with Ha = 0 at the same Reynolds number
RePeak-speed
decrease (%)
Mean wall-line
decrease (K)
Maximum sampled
wall decrease (K)
Ha = 10 maximum
sampled wall (K)
25025.850.79910.000121262.62
50025.610.80510.07361942.33
75024.760.79430.14648834.47
1,00023.520.77550.19977780.33

“Maximum sampled wall decrease” means max(Tw, Ha 0) − max(Tw, Ha 10) on the exported wall line. It is different from the largest local value of Tw(Ha 0) − Tw(Ha 10).

WHY THE DEFINITION MATTERS

A 1.21 K local decrease
can coexist with almost
no change in the maximum.

At Re = 250, the largest local wall-temperature decrease is 1.21 K. Yet the decrease in the maximum sampled wall temperature is only 0.00012 K—negligible compared with its absolute temperature; numerical uncertainty is unquantified.

The Ha = 10 maximum sampled wall temperature still reaches 1,262.62 K at Re = 250, compared with 780.33 K at Re = 1,000. Constant material properties over this temperature range require further assessment.

How the profiles and thermal metrics are calculated

Velocity: Vref is the trapezoidal height-mean speed of the Ha = 0 profile at each Re. All five Ha curves share that value. V denotes speed magnitude; its height integral is not a signed mass-flow calculation.

Wall response: compare temperatures at identical x and Re. Axial means use a trapezoidal integral over the complete exported span, approximately 300 mm, including both endpoints.

Reference heat-transfer indices: href = q″/(Tw − Tc), and Nuref = href Dh/k. Tc is the centerline temperature. At Ha = 10, the mean Nuref increase is 3.14–3.37%; this is a centerline-referenced index, not a conventional bulk-temperature Nusselt number.

The wall heat flux is confirmed in all 20 native setups. A conventional bulk coefficient still requires matched mass-flow-weighted cross-sectional temperatures. href and Nuref are related by a constant factor and are not independent performance measures.

03 / EVIDENCE & NEXT STEPS

A traceable comparison.
Clear limits on the conclusion.

Recomputed numbers agree with the earlier figure data. The portfolio adds a check against the native case settings and mesh, and keeps the uncertainty around physical performance visible.

VERIFIED FOR THIS EDITION

Inputs and calculations

  • Twenty Re/Ha labels mapped to native Fluent cases.
  • Channel dimensions, mesh counts, lower-wall heat flux and localized magnetic field checked.
  • Original CSVs parsed independently; all 100 points retained.
  • Common baseline, actual coordinates and trapezoidal averages used consistently.
  • Native sampling locations recovered from the CFD-Post state.
STILL TO BE ESTABLISHED

Numerical and physical confidence

  • A complete convergence audit, residual review and conservation checks for the full case matrix.
  • Mesh sensitivity, particularly near the walls and magnetic-field transitions.
  • Temperature-dependent properties and appropriate thermal operating limits.
  • Bulk-temperature heat transfer, pressure loss and equal-pumping comparisons.
  • Benchmark or experimental validation before applying the results to hardware.

Dense line sampling describes a solved field; it does not establish mesh independence. The small thermal differences have no quantified numerical uncertainty. Earlier pumping-power figures are outside the verified comparison presented here.

04 / REPORT & REUSABLE DATA

Read the study.
Inspect the numbers.

A newly written portfolio report combines the verified setup with figures rebuilt from the original exports. The downloadable tables preserve the metric definitions and all 20 cases.

Cover of the new MHD flow and thermal response portfolio reportIllustrated report · September 2026 ↗