MHD channel portfolio data — revision 01 — 2026-09-28 Study: 20 saved steady laminar Fluent cases; Re = 250, 500, 750, 1000 and Ha = 0, 2.5, 5, 7.5, 10. Geometry: 300 mm long, 10 mm high; lower wall 100000 W/m2; upper wall adiabatic; inlet 600 K. Fluid: constant-property PbLi. rho = 9806 kg/m3, mu = 0.00193 Pa s, cp = 189.5 J/(kg K), k = 20.93 W/(m K), sigma = 782000 S/m. Re = rho Uin Dh / mu, Dh = 0.020 m. Ha = |B| a sqrt(sigma/mu), a = 0.005 m. The applied field is directed -y in x = 0.050–0.250 m. comparison-data.csv: one row per case. All reduction metrics use the Ha = 0 case at the same Re as baseline. Positive reduction means a smaller selected-case value. speed-profile-data.csv: 100 original speed samples per case, 2000 total; cross-channel line x = 0.150 m. V is speed magnitude, not signed axial velocity. thermal-line-data.csv: 100 paired wall/centerline samples per case, 2000 total. Wall line y = 0; centerline y = 0.005 m. The original source named Bulk Temperature contains centerline temperature. Means are trapezoidal integrals divided by the actual exported coordinate span, including both endpoints. No smoothing is applied. Each speed profile is normalized by its Re group's zero-field height-mean speed. Integrated speed magnitude is not a mass-conservation test. Mean wall reduction: mean(Tw at Ha0 - Tw at selected Ha), over the approximately 300 mm sampled line. Maximum local wall reduction: max over matched positions of (Tw at Ha0 - Tw at selected Ha). Reduction of maximum sampled wall: max(Tw at Ha0) - max(Tw at selected Ha). This is different from maximum local wall reduction, and only covers the exported line. h_ref = q/(Tw - Tc), Nu_ref = h_ref Dh/k; Tc is centerline temperature. These are centerline-referenced indices, not conventional bulk-temperature coefficients. Native case settings, mesh counts and CFD-Post sampling locations were checked. Three original CSVs were independently parsed and recomputed; results agree with the previous editable chart data. The saved numerical comparison does not establish mesh independence, physical validation, uncertainty bounds, pressure-loss benefits or overall efficiency. Temperature-dependent properties and high-temperature physical feasibility remain open.