UPSat / REDUCED-ORDER THERMAL MODELLING
From board physics
to a compact
thermal model.
Four PCB models. Sixteen temperature states per board. A traceable connection between CFD and thermal circuits.
Explore the COMMS result ↓Historical UPSat CAD visualization · Andreas Ampatzoglou / AML-UP, via Libre Space Foundation · CERN OHL v1.2
An independent study by Ramin (Ray) Mashayekhi using open hardware. The contribution is the geometry-to-CFD workflow, regional reduction, thermal RC models and numerical verification.
Illustrated report & data ↓HARDWARE TO MODEL
Four boards.
One modelling language.
Explore each board’s original CAD view, native layout, configured heat-source regions and expanded resistance-capacitance network.
COMMS · Communications
4 heat-source groups · 720 s mixed transient complete

Each network represents an independent homogeneous PCB sheet. The OBC render has partial component population; the EPS board render excludes batteries. OBC and EPS heat-source footprints still require reconciliation with native component positions.
MODEL & METHOD
Keep the heat paths.
Reduce the state count.
The finite-volume solution resolves the sheet temperature field. Sixteen area-weighted regional means become the states of a compact thermal network.
- 01
Define the sheet
Prepare source regions and four circular mounting ports. Prescribe source powers and mount temperatures.
- 02
Solve the basis cases
34 steady calibration cases across four boards: individual source and mount excitations.
- 03
Build the RC model
Fit positive conductances; map source power by area; derive regional heat capacities from the sheet material.
- 04
Compare withheld loads
Check temperatures and mount heat flows against saved CFD, then verify the circuit implementation.
The thermal abstraction
- Sheet envelope
- 92.5 × 92.5 mm; 1.6 mm effective thickness
- Material model
- Homogeneous sheet; density 1,850 kg/m³ and specific heat 900 J/(kg·K)
- Network
- 4 × 4 regional states; 24 in-plane links and 4 links to prescribed mounting ports
- Heat storage
- Cᵢ = ρ t Aᵢ cₚ; total sheet capacity 22.713679 J/K per board
- Reference temperature
- 293.15 K (20 °C)
THERMAL RESISTANCE–CAPACITANCE MODEL
C dT/dt + K T = B P + Gm Tm
C stores heat. K connects the regional temperatures. B distributes source powers. GmTm represents the prescribed mount temperatures.
Temperature ↔ voltage · heat flow ↔ current
Resistance: K/W · capacitance: J/K
Capacitor ground is a storage reference. The four mount ports define the physical boundary paths. Component and package thermal masses are outside this sheet model.

STEADY NUMERICAL COMPARISON
A field, sixteen means,
and a separate prediction.
The three views show different quantities: native cell temperatures, extracted CFD regional means and the reduced model’s predicted regional temperatures.

| Board | Calibration cases | RMSE · K | Maximum absolute error · K | Transient evidence |
|---|---|---|---|---|
| COMMS | 8 | 0.164 | 0.299 | 720 s mixed transient complete |
| ADCS | 8 | 0.664 | 1.179 | 120 s source-step pilot |
| OBC | 8 | 0.474 | 1.083 | Transient comparison pending |
| EPS | 10 | 1.002 | 2.007 | 2,000 s mount-step pilot |
The boards use different synthetic power distributions. These results compare each reduced model with its own CFD reference; they do not rank the thermal performance of the real boards.
COMPLETED COMMS TRANSIENT
Follow the response.
Inspect the difference.
A withheld sequence changes source powers and mounting temperatures over 720 seconds. The saved calculation contains 1,080 time steps and 1,081 recorded samples.
N01 is the lower-left region. Select a state to compare its full recorded history.
- Loading saved data
- —
N11 · regional temperature
The chart shows saved numerical results. The controls select a series and timestamp.
Temperature RMSE pools all 16 states and 1,081 records, including t = 0. Mount-flow RMSE pools four ports and 1,080 records after t = 0. Both use equal sample weights, not elapsed-time weights. Mount heat flow is positive into the PCB. Errors are RC minus CFD.

View the original response, error and energy figures


VERIFICATION & INTERPRETATION
Check the reduction.
Keep the physical limits visible.
The saved evidence separates discretization, solver convergence, network agreement and circuit implementation.

DISCRETIZATION
One steady mesh comparison
Five COMMS meshes span 5,226–68,032 cells. Increasing the selected M3 mesh to M5 changes peak temperature by 0.0398 K and the largest regional mean by 0.0388 K in the tested steady case.
This is evidence for that load case. Transient and source-specific sensitivity remain separate checks.
IMPLEMENTATION
A circuit checked against its equations
The corrected LTspice networks use the same regional states, resistances, capacitances and source weights as the RC equations. Circuit-to-equation checks test the implementation; the CFD comparison tests the reduction.
The archived original circuit exports contained a node-indexing error. The current study uses the corrected implementation.
Mesh sensitivity and steady solver audit


Where the model applies
- COMMS: completed 720 s withheld transient comparison with the homogeneous sheet CFD reference.
- ADCS and EPS: focused source-step and mount-step pilots, respectively. These have different loads and durations.
- OBC: steady comparison complete; transient CFD comparison pending.
- Physical scope: no measured hardware correlation, component-junction validation or flight-temperature prediction. Package masses, full contact paths, radiation and the coupled spacecraft environment require further modelling.

REPORT & REUSABLE EVIDENCE
The complete story.
The numbers behind it.
A freshly authored illustrated case study brings together original hardware views, model definitions, native fields, network diagrams and checked numerical comparisons.
UPSat · CFD to thermal RC models ↗Open-hardware attribution
Historical spacecraft CAD: © 2014–2016 Andreas Ampatzoglou and AML-UP, via Libre Space Foundation, under CERN OHL v1.2. Board layouts come from the UPSat subsystem repositories. COMMS hardware: © 2016 Manos Theodoridis, APEL / University of Patras; Libre Space Foundation and contributors. Original board credits and licences accompany the parameter download. Original structural design · Subsystem reference.
The independent UPSat modelling study is separate from the author’s Ex-Alta 3 team contribution.