Module architecture
Populated board, optical receptacle, enclosure and thermal stack, with original assembled, exploded and cutaway views and saved geometry checks.
HIGH-SPEED CONNECTORS / OSFP MODULES
An ongoing engineering project connecting electronic packaging, mechanical interfaces and thermal analysis.
The work spans a detailed optical-module reconstruction, a single-module conduction model and an eight-module liquid-cooling assembly.

WORK TO DATE
Populated board, optical receptacle, enclosure and thermal stack, with original assembled, exploded and cutaway views and saved geometry checks.
Six mesh levels and an all-solid thermal setup are prepared. The latest saved campaign stopped before solver iterations; no mesh recommendation is available.
The latest design combines eight modules with a 30-minichannel cold plate. Mesh import and interface setup still need correction before the intended 1 L/min case can be solved.
These are separate model branches. Their geometry, heat loads and cooling conditions differ, so setup evidence from one branch does not establish results for another.
DETAILED REFERENCE CAD
The populated board sits within a reconstructed enclosure, with lid, heat spreader, thermal pads, retention details, fasteners and internal optical connections. The model makes these relationships visible while the mechanical design continues to develop.

KiCad and component models define the populated board reference. CadQuery and STEP bring the mechanical architecture into the assembled package. Saved export and reimport records document 3,080 valid solids, 53,006 faces and 42 stored colours.
Component instances, named groups and CAD solids describe different levels of the representation. Colours distinguish objects for inspection. Neither the counts nor the colours establish a physical bill of materials or verified material identities.
PCB & OPTICAL INTERFACES
The detailed board has 168 populated component instances using fifteen component-model types and sixty logical edge-contact positions. Its 2,984 STEP solids include package-level geometry rather than separate purchased parts.


Selected outer nominal constraints follow public references. Internal arrangement, dimensions, materials and interfaces include generic assumptions recorded in the source work.
The next design checks include latch movement, plug access, tolerances and the thermal contact stack. Electrical, optical and signal-integrity performance require their own design and verification evidence.
THERMAL ANALYSIS IN DEVELOPMENT

The reference thermal stack defines eight package-to-spreader pads and one spreader-to-lid pad. Simplified geometry carries the main package and heat-transfer paths into model preparation without retaining every small lead or contact.
01 / SINGLE MODULE
Earlier setup checks document six unsolved polyhedral meshes. The later saved campaign records all six cases as failed at zero iterations, with no temperature or heat-balance results.
Current status: setup and solver recovery are required before convergence and mesh sensitivity can be assessed. The related transient branch also remains under development.
02 / EIGHT-MODULE ASSEMBLY · v11
The latest package contains geometry, a mesh, material and heat-source tables, and an intended steady conjugate heat-transfer setup. Its saved import attempt reports face-zone errors and skipped zones; a usable completed solver case is not established.
Current status: correct the mesh and zone interfaces, then verify the model before solving. The 320 W and 1 L/min values are design inputs, not achieved cooling performance.
The v11 baseline uses effective material properties, perfect thermal coupling and adiabatic outer walls. Its laminar-flow assumption needs review around the headers and ports. The single-module model uses a prescribed cold surface instead of predicting coolant behaviour.
Successful case reopening, valid mesh and interface checks, converged residuals, stable engineering monitors, energy balance and consistent mesh comparisons are still required. Physical or trusted reference comparisons will then be needed to assess the model assumptions.
CONTINUING THE WORK
Check component dimensions, materials, latch movement, optical access and contact tolerances against verified data.
Repair face-zone and interface definitions in the eight-module model, confirm units and power totals, and verify saved cases reopen correctly.
Recover the single-module campaign and solve the cooling model with documented convergence, energy balance and mesh checks. Add time-step checks when transient analysis is ready.
Add temperature fields, pressure-drop results and engineering conclusions when the calculations and their limits can be supported by the saved evidence.
This is an independent public-reference study. It does not imply manufacturer affiliation, proprietary CAD access or a production-qualified design. Geometry and setup checks cited here are saved project evidence; no new simulation or hardware test was performed for this portfolio update.
PROJECT RECORD · 28 SEPTEMBER 2026
Original editable CAD, setup files and detailed source records are preserved in the project library. This page and report are a progress snapshot and will be updated as the engineering work develops.