RM↗Ramin (Ray) MashayekhiMECHANICAL ENGINEER-IN-TRAININGLet’s talk ↗
← Engineering projects

HIGH-SPEED CONNECTORS / OSFP MODULES

Designing the module.
Developing the cooling.

An ongoing engineering project connecting electronic packaging, mechanical interfaces and thermal analysis.

The work spans a detailed optical-module reconstruction, a single-module conduction model and an eight-module liquid-cooling assembly.

OSFP reference module cutaway showing its populated PCB and mechanical enclosure
Original CAD render from the saved detailed reference model. Internal layout and materials include reconstruction assumptions.Full size ↗

WORK TO DATE

From reference geometry
toward a verified model.

REFERENCE CAD · DOCUMENTED

Module architecture

Populated board, optical receptacle, enclosure and thermal stack, with original assembled, exploded and cutaway views and saved geometry checks.

SINGLE MODULE · UNFINISHED

20 W conduction study

Six mesh levels and an all-solid thermal setup are prepared. The latest saved campaign stopped before solver iterations; no mesh recommendation is available.

EIGHT MODULES · IN DEVELOPMENT

320 W liquid cooling

The latest design combines eight modules with a 30-minichannel cold plate. Mesh import and interface setup still need correction before the intended 1 L/min case can be solved.

These are separate model branches. Their geometry, heat loads and cooling conditions differ, so setup evidence from one branch does not establish results for another.

DETAILED REFERENCE CAD

Separate the parts.
Follow the interfaces.

The populated board sits within a reconstructed enclosure, with lid, heat spreader, thermal pads, retention details, fasteners and internal optical connections. The model makes these relationships visible while the mechanical design continues to develop.

POPULATED PCB
168 instances
EDGE INTERFACE
60 logical positions
ADDED MECHANICAL GROUPS
65 named groups
SAVED STEP CHECK
3,080 valid solids
Complete OSFP reference enclosure
Complete reference module, rendered from saved CAD.Full size ↗

Geometry evidence

KiCad and component models define the populated board reference. CadQuery and STEP bring the mechanical architecture into the assembled package. Saved export and reimport records document 3,080 valid solids, 53,006 faces and 42 stored colours.

How to read the model

Component instances, named groups and CAD solids describe different levels of the representation. Colours distinguish objects for inspection. Neither the counts nor the colours establish a physical bill of materials or verified material identities.

PCB & OPTICAL INTERFACES

Packaging detail,
with clear assumptions.

The detailed board has 168 populated component instances using fifteen component-model types and sixty logical edge-contact positions. Its 2,984 STEP solids include package-level geometry rather than separate purchased parts.

Original detailed OSFP PCB reference render
Detailed populated-board reference. A functional schematic and validated electrical routing remain outside the demonstrated work.Full size ↗
Close-up of the reconstructed optical receptacle
Original optical-receptacle CAD detail. Fit, access and optical routing still require verified component data.Full size ↗

Independent engineering reconstruction

Selected outer nominal constraints follow public references. Internal arrangement, dimensions, materials and interfaces include generic assumptions recorded in the source work.

The next design checks include latch movement, plug access, tolerances and the thermal contact stack. Electrical, optical and signal-integrity performance require their own design and verification evidence.

THERMAL ANALYSIS IN DEVELOPMENT

Two scales.
Different cooling questions.

Simplified OSFP geometry prepared for the single-module conduction model
Single-module geometry preparation. The lid and thermal stack are hidden to show retained package blocks; this is a CAD view, not a temperature contour.Full size ↗

The reference thermal stack defines eight package-to-spreader pads and one spreader-to-lid pad. Simplified geometry carries the main package and heat-transfer paths into model preparation without retaining every small lead or contact.

01 / SINGLE MODULE

Steady solid conduction

Assumed load
20 W total
Cooling condition
Top patch fixed at 25 °C
Model
Solid conduction; no coolant domain
Mesh plan
Six levels, M01–M06

Earlier setup checks document six unsolved polyhedral meshes. The later saved campaign records all six cases as failed at zero iterations, with no temperature or heat-balance results.

Current status: setup and solver recovery are required before convergence and mesh sensitivity can be assessed. The related transient branch also remains under development.

02 / EIGHT-MODULE ASSEMBLY · v11

Liquid-cooled cold plate

Assumed load
8 × 40 W = 320 W
Coolant input
Water, 1 L/min at 25 °C
Cold plate
30 minichannels
Module interfaces
Eight nonconformal contacts

The latest package contains geometry, a mesh, material and heat-source tables, and an intended steady conjugate heat-transfer setup. Its saved import attempt reports face-zone errors and skipped zones; a usable completed solver case is not established.

Current status: correct the mesh and zone interfaces, then verify the model before solving. The 320 W and 1 L/min values are design inputs, not achieved cooling performance.

Assumptions still to test

The v11 baseline uses effective material properties, perfect thermal coupling and adiabatic outer walls. Its laminar-flow assumption needs review around the headers and ports. The single-module model uses a prescribed cold surface instead of predicting coolant behaviour.

What will establish thermal results

Successful case reopening, valid mesh and interface checks, converged residuals, stable engineering monitors, energy balance and consistent mesh comparisons are still required. Physical or trusted reference comparisons will then be needed to assess the model assumptions.

CONTINUING THE WORK

Next steps
before performance claims.

  1. Refine the mechanical definition

    Check component dimensions, materials, latch movement, optical access and contact tolerances against verified data.

  2. Resolve the current solver setup

    Repair face-zone and interface definitions in the eight-module model, confirm units and power totals, and verify saved cases reopen correctly.

  3. Complete and compare the solutions

    Recover the single-module campaign and solve the cooling model with documented convergence, energy balance and mesh checks. Add time-step checks when transient analysis is ready.

  4. Publish traceable results

    Add temperature fields, pressure-drop results and engineering conclusions when the calculations and their limits can be supported by the saved evidence.

This is an independent public-reference study. It does not imply manufacturer affiliation, proprietary CAD access or a production-qualified design. Geometry and setup checks cited here are saved project evidence; no new simulation or hardware test was performed for this portfolio update.

PROJECT RECORD · 28 SEPTEMBER 2026

Explore the
work in progress.

Original editable CAD, setup files and detailed source records are preserved in the project library. This page and report are a progress snapshot and will be updated as the engineering work develops.