RM↗Ramin (Ray) MashayekhiMECHANICAL ENGINEER-IN-TRAININGLet’s talk ↗
← All projects

ASTER CP01 / INDEPENDENT ENGINEERING STUDY

Four cores.
One cooling question.

How much thermal improvement is worth the pressure loss?

A cold plate study from mechanical assembly and structured meshing to conjugate heat transfer and engineering comparison.

Preliminary numerical comparison · September 2026
Exploded copper cold plate with straight-channel core, lid, seals and mounting hardware
Original CAD / native Blender render

EXPLORE THE INTERNAL GEOMETRY

Straight channels

Parallel fins add wetted area and guide the coolant through the core.

Close-up of parallel copper fins
Explore the CFD comparison ↓
FOUR GEOMETRIES
One comparison basis
INLET REYNOLDS NUMBER
1,000
WATER AT INLET
25 °C
NOMINAL HEAT INPUT
1,000 W

01 / THE ENGINEERING FINDING

More heat-transfer area.
A larger hydraulic cost.

Inside a common copper assembly, the internal core changes how water reaches the heated region. I developed this early-stage study to compare a plain cavity, straight channels, wavy channels and pin fins on the same modelling basis.

The saved channel cases show about 66% lower heater thermal resistance than Plain, alongside 5.6–5.8 times its hydraulic power. Straight and Wavy differ by only 0.4% in thermal resistance. Their energy runs stopped early, so that small difference cannot support a final ranking.

This is an independent design and numerical study. The results describe the saved model at one inlet condition; hardware performance has not been established.

02 / MY WORK & METHOD

From the assembly
to the physics.

Mechanical design, CAD preparation, structured hexahedral meshing, CFD post-processing and technical visualization form one connected workflow.

01

Define the assembly

Copper base and lid, coolant ports, seals and spring mounting hardware establish the mechanical concept.

Detailed cold-plate assembly with seals and fasteners
02

Simplify with purpose

Remove fastener and seal detail from the thermal-fluid model while retaining the copper and core flow passages.

Simplified copper lid and finned base for analysis
03

Resolve the heat path

Two copper bodies and three fluid bodies support the conjugate heat-transfer calculation, with extended inlet and outlet passages.

Exploded simplified model showing copper and coolant domains

A common operating point

Inlet
25 °C water · Re = 1,000
8 mm diameter · 0.11157 m/s
Heat source
1,000 W nominal input
Nominal 50 × 50 mm heater footprint
Outlet
0 Pa gauge averaged static pressure
Reference pressure: 1 atm
Extensions
50 mm at inlet and outlet

Modelling choices

  • Steady laminar flow and constant-property, single-phase water.
  • Copper conduction coupled to the coolant; no-slip walls and insulated exterior.
  • Flow solved first, followed by an energy solution with the flow field held fixed.
  • Native Ansys CFX results exported through CFD-Post for consistent comparison.

The high predicted wall temperatures require an operating-pressure and phase-change assessment before treating this as a practical operating point.

03 / RESULTS & INTERPRETATION

See both sides
of the trade-off.

Results below were checked against the original exported quantities. Pressure loss is measured between the original plate ports, excluding the computational extensions.

The cooling / pumping trade-off

Relative to Plain = 1.00 · same inlet Reynolds number

CoreHeater thermal resistance lower is favourableHydraulic power lower is favourable
Plain cavity
1.000×
1.00×
Pin fin
0.518×
2.27×
Straight
0.339×
5.58×
Wavy
0.340×
5.85×

The columns use different scales: thermal resistance 0–1×; hydraulic power 0–6×. These saved fields are preliminary; only Plain met the requested energy target.

Saved CFD comparison at inlet Re = 1,000
CoreThermal resistance
K/W
Plate pressure loss
Pa
Peak underside
°C
Energy target
Plain cavity0.1538710.02193.4Reached
Pin fin0.0796822.75114.0Stopped early
Straight0.0521855.8885.2Stopped early
Wavy0.0523958.5585.5Stopped early
How the comparison metrics are defined

Heater thermal resistance: (heat-weighted heater temperature − inlet bulk temperature) / integrated heater heat input. It uses the heated region’s weighted temperature.

Plate pressure loss: mass-flow-weighted total pressure at the original inlet minus that at the original outlet.

Hydraulic power: plate total-pressure loss × volumetric flow. This is fluid power; pump efficiency and the rest of a cooling loop are outside this metric.

Peak underside temperature: the maximum on the exported underside locator. It is not a claimed maximum over every solid body.

THE RESULT THAT NEEDS JUDGEMENT

Wavy raises a local metric.
The whole-heater outcome barely changes.

Wavy’s mean sectional Nusselt number is 10.1% higher than Straight’s. Yet its heater thermal resistance is 0.4% higher and its hydraulic power is 4.8% higher in the saved fields. A local heat-transfer metric alone does not establish a better cold plate.

The next decision is verification: complete both energy solutions and check mesh sensitivity before preferring one channel design.

Native midplane velocity contours for Plain, Pin, Straight and Wavy on a shared scale
Native velocity fields at z = 6.5 mm. One colour scale is used across all four geometries; all results are preliminary.Full size ↗

04 / MESHES, REDUCTION & VERIFICATION

Make the comparison
reviewable.

Structured mesh topology and consistent extraction make the result traceable. Numerical checks define how far the interpretation can go.

Structured hexahedral mesh topology illustration for Plain cavity
Plain cavity
Structured hexahedral mesh topology illustration for Pin fin
Pin fin
Structured hexahedral mesh topology illustration for Straight channels
Straight channels
Structured hexahedral mesh topology illustration for Wavy channels
Wavy channels

These native mesh images illustrate mesh topology. They show a separate mesh revision from the solved four-core comparison below.

The solved comparison

Plain
4,044,160 hex cells · target reached
Pin fin
5,724,696 hex cells · stopped early
Straight
5,252,212 hex cells · stopped early
Wavy
5,252,212 hex cells · stopped early

Energy RMS target: 10−11. The three interrupted runs remain preliminary even where their global heat balances are close.

1,000 stations per case

Axial exports resolve how bulk temperature, wall temperature, heat transfer and pressure loss change through the plate. The common valid core contains 732 stations and 731 adjacent intervals.

Sectional Nusselt numbers are averaged over the common valid intervals. Dense sampling adds spatial detail; it does not improve the underlying mesh or establish solution accuracy.

A separate five-level Plain mesh study remains provisional because pressure monitors were drifting and sampled heater coverage changed. Mesh independence is not established for the four-core ranking.

Remaining verification and mechanical-design work
  1. Complete the requested energy convergence and confirm stable thermal and pressure monitors.
  2. Repeat mesh sensitivity checks with consistent heater coverage and operating conditions.
  3. Review temperature-dependent properties, operating pressure and boiling feasibility.
  4. Compare additional flow rates and equal hydraulic power before choosing an application-specific design.
  5. Resolve seal qualification, screw engagement, lateral location and clamp load before any manufacturing release.
Related mechanical design & proposed GD&T study ↗

05 / ORIGINAL PROJECT MEDIA

The assembly,
in motion.

The native Blender sequence shows each complete copper base changing within the same mechanical assembly, with a matching core detail at a common scale.

Explore the study in the newly written report, or inspect the numerical comparison directly.

Native CAD renders, mesh illustrations and CFD field exports from the Aster CP01 project. Report prepared September 2026 from the original project resources.

Plain → Straight → Wavy → Pin fin · Native geometry animation