POROUS CHANNEL | PORTFOLIO DATA DEFINITIONS | 28 SEPTEMBER 2026 Independent reprocessing of saved native exports and audit of native setup/status/log files; CFX solver not rerun. Scope: 28 native completed thermal cases out of 52 planned; 13 reduced-metric cases; ten illustrated comparisons. All primary pressure/power comparisons span x=0–300 mm of a 1 m channel. Modelled width is 0.1 mm. Legacy 1 m values are labelled separately. CSV blanks mean not applicable or no native scalar export; do not substitute zero. Three additional empty baselines have sampled peaks but no native wall max/area-mean in this extraction. Re_H: rho U_in H / mu with H=0.010 m; prescribed inlet speed defines the case label. Da_H: K/H^2 with H=0.010 m; not applicable for empty channel. wall_area_mean_C: Geometric-area-weighted mean of native CFD-Post areaAve(Temperature) on heated_f and heated_p over x=0–300 mm; water temperature. wall_peak_C: Maximum of native maxVal(Temperature) on heated_f and heated_p; water temperature at heated boundary. R_peak_K_W: (native heated-wall maximum temperature - inlet temperature) / actual integrated heat input. Q_W: 5000 (Af + 0.95 Ap), independently reconciled to printed solver boundary heat flows: 0.150 W empty, 0.145 W porous. dp_0_300_Pa: Area-averaged static pressure at inlet x=0 minus area-averaged static pressure on cross-section x=0.300 m. porous_flow_fraction_percent: 100*abs(massFlow at porous-only x=0.150 m plane / massFlow at all-domain x=0.150 m plane). Net signed flux ratio; reverse flow may occur elsewhere. pumping_power_W: dp_0_300 * abs(inlet mass flow)/rho for the 0.1 mm numerical width; hydraulic static-pressure power, no pump efficiency. Nu_Dh_mean_local_120: Arithmetic mean at 120 equally spaced x midpoints of q_geometric(x) Dh/[k_water (Twall(x)-Tbulk(x))], Dh=0.020 m. Nu_Dh_overall: mean(q_geometric) Dh/[k_water mean(Twall-Tbulk)] at the same 120 midpoints; differs from mean local Nu. f_Darcy_mean: 2 dp_0_300 Dh/(rho U_extracted^2 L), L=0.300 m; apparent factor including entrance and porous losses. f_Fanning_mean: f_Darcy_mean/4. PEC_overall: (Nu_overall/Nu_overall_empty)/(f_Darcy/f_Darcy_empty)^(1/3), matched Re; screening index, not direct equal-power simulation. mass_deviation_max_percent: Largest absolute deviation of 121 section mass-flow magnitudes from extracted inlet mass-flow magnitude, divided by inlet magnitude ×100. sensible_heat_closure_0_300_percent: 100 [Q-mdot_in cp (Tb_300-Tin)] / Q; a section sensible-heat diagnostic, not the solver normalised energy imbalance. sampled_hotspot_x_mm: Location of highest temperature on saved 1201-point wall line; sampling limits apply. mean_Nu_interpolation_change_percent: Change after interpolation from saved profiles to 1200 midpoints; postprocessing sampling sensitivity, not a new mesh run. LIMITATIONS No mesh independence, experimental validation, foam calibration or quantified physical uncertainty has been established. Constant-property steady laminar planar model with separate water and copper energies (LTNE). Trial interfacial HTC 10000 W/m²K and area density 9308 m⁻¹ are independent assumed constants; no pore-size/permeability consistency is claimed. Thermal solves freeze the flow field at its 1e-5 RMS flow-stage target; a 1e-12 thermal target does not establish fully coupled flow sensitivity. Heated porous boundary supplies heat to fluid, with adiabatic copper boundary. Actual heat loads differ by 3.33% between empty and porous cases. The 0–300 mm static-pressure difference excludes the downstream 300–1000 mm section. Legacy full-channel pressure ratios cannot be mixed with these results. Mean local Nu changes by 1.6–11.9% under a 120-to-1200-point interpolation check; overall Nu changes by less than 0.16%. Sensible heat closure diagnostic reaches approximately -2.36% for Hp=5 mm, Da=1e-5 and -2.10% for Hp=5 mm, Da=1e-4. These differences need review; small equation residuals alone do not settle them. 28 native cases have completed RMS acceptance; this report verifies the saved 13-case detailed extraction and ten illustrated scalar comparisons, not a 52-case optimum. Three extra empty-channel baselines have local profile metrics but no saved native heated-boundary max/area-mean scalar extraction in the illustrated source set. Their sampled wall peaks are labelled separately.